1 option
Analysis of Open-Switch Fault Two Level Three Phase Voltage Inverter Behaviour and Automatic Detection and Location Using Zero Harmonic Component University of Boumerdes, Algeria
- Format:
- Conference/Event
- Author/Creator:
- Benslimane, T., author.
- Conference Name:
- SAE World Congress & Exhibition (2007-04-16 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2007
- Summary:
- The faulty performance of two level three phase voltage inverter is studied under open-switch conditions. This inverter is three phase two level six IGBT voltage source inverter feeding a three phase balanced resistive-inductive load. The inverter three phases currents zero harmonic components are used as diagnostic indices. A knowledge algorithm is based to get information on which IGBT is in open-switch fault condition. This algorithm testing shows that the system could not only detect the open-switch fault, but also identify the faulty switch. Presented simulation results confirm the effectiveness of the proposed methodology