My Account Log in

1 option

Performance Evaluation of Double-condenser Loop Heat Pipe Onboard Monitor of All-sky X-ray Image (MAXI) in Thermal Vacuum Testing

SAE Technical Papers (1906-current) Available online

View online
Format:
Conference/Event
Author/Creator:
Nagai, Hiroki, author.
Conference Name:
International Conference On Environmental Systems (2005-07-11 : Rome, Italy)
Language:
English
Physical Description:
1 online resource
Place of Publication:
Warrendale, PA SAE International 2005
Summary:
The thermal performance of the Loop Heat Pipe Radiator System (LHPRS) has been verified in the thermal vacuum testing. LHPRS is used as the heat transport system to reject heat from the Monitor of All-sky X-ray Image (MAXI). Since this LHPRS was designed exclusively for the MAXI system, it has two-condensers in parallel connected to a common evaporator. Since it is possible that the heat transportation deviates to one condenser only, it had to be investigated how the double condensers affect the LHPRS performance under various conditions. Thermal vacuum testing was conducted for the engineering model of the MAXI/LHPRS. In this paper, the test result and performance verification of the MAXI/LHPRS are described
Notes:
Vendor supplied data
Publisher Number:
2005-01-2939
Access Restriction:
Restricted for use by site license

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.