1 option
Performance Evaluation of Double-condenser Loop Heat Pipe Onboard Monitor of All-sky X-ray Image (MAXI) in Thermal Vacuum Testing
- Format:
- Conference/Event
- Author/Creator:
- Nagai, Hiroki, author.
- Conference Name:
- International Conference On Environmental Systems (2005-07-11 : Rome, Italy)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2005
- Summary:
- The thermal performance of the Loop Heat Pipe Radiator System (LHPRS) has been verified in the thermal vacuum testing. LHPRS is used as the heat transport system to reject heat from the Monitor of All-sky X-ray Image (MAXI). Since this LHPRS was designed exclusively for the MAXI system, it has two-condensers in parallel connected to a common evaporator. Since it is possible that the heat transportation deviates to one condenser only, it had to be investigated how the double condensers affect the LHPRS performance under various conditions. Thermal vacuum testing was conducted for the engineering model of the MAXI/LHPRS. In this paper, the test result and performance verification of the MAXI/LHPRS are described
- Notes:
- Vendor supplied data
- Publisher Number:
- 2005-01-2939
- Access Restriction:
- Restricted for use by site license