Summary:
This paper presents a combustion stability index derived from an in-cylinder ionization signal to control the engine maximum EGR limit. Different from the existing approaches that use the ionization signal values to gauge how much EGR was added during the combustion, the proposed method concentrates on using the ionization signal duration and its stochastic properties to evaluate the end result of EGR on combustion stability. When the duration index or indexes are higher than pre-determined values, the EGR limit is set. The dynamometer engine test results have shown promise for closed loop EGR control of spark ignition engines