1 option
Diesel Particulate Filter Burner System Modeling, Control and Diagnosis Woodward Incorporated
- Format:
- Conference/Event
- Author/Creator:
- Fang, Fang, author.
- Conference Name:
- Commercial Vehicle Engineering Congress (2011-09-13 : Chicago, Illinois, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2011
- Summary:
- Current and future emission levels on Particulate Matter (PM) will require diesel engines to use Diesel Particulate Filters (DPF). One of the challenges of using a DPF is the requirement to generate high temperature exhaust flow (typically 550 - 650 degrees C) to enable filter regeneration, especially at cold temperatures and transient conditions. Maintaining constant temperature and low emissions during regeneration presents a number of controls challenges. This is especially true for burner systems which have complex air, fuel, and ignition systems. This paper outlines the controls and diagnostics of a burner system. Details of the burner system component modeling, thermal modeling of combustion, combustion flame detection, and system control and diagnostics are also illustrated. Application data is presented to demonstrate performance and robustness of the system at different engine conditions
- Notes:
- Vendor supplied data
- Publisher Number:
- 2011-01-2210
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.