1 option
Engine Cooling System with a Heat Load Averaging Capability Aqwest, LLC
- Format:
- Conference/Event
- Author/Creator:
- Vetrovec, John, author.
- Conference Name:
- SAE World Congress & Exhibition (2008-04-14 : Detroit, Michigan, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2008
- Summary:
- There is a need for an automotive engine cooling system capable of handling increased heat load while, at the same time, having reduced size and weight. This paper evaluates a concept for an engine cooling system with a passive heat accumulator that averages out peak heat loads. Heat load averaging permits relaxation of the cooling system requirements and allows substantial reduction of system size and weight. This also translates to a smaller coolant inventory allowing for faster engine warm-up and reduced emissions of harmful pollutants during a cold engine start
- Notes:
- Vendor supplied data
- Publisher Number:
- 2008-01-1168
- Access Restriction:
- Restricted for use by site license