1 option
Test Results for a High Power Thermal Management System ATK Space Division
- Format:
- Conference/Event
- Author/Creator:
- Wrenn, Kimberly R., author.
- Conference Name:
- International Conference On Environmental Systems (2008-06-29 : San Francisco, California, United States)
- Language:
- English
- Physical Description:
- 1 online resource
- Place of Publication:
- Warrendale, PA SAE International 2008
- Summary:
- In response to the identified needs of emerging high power spacecraft applications, a multiple evaporator Hybrid Loop Heat Pipe (H-LHP) was developed and tested as part of a Dual Use Science and Technology (DUS&T) program co-sponsored by ATK and AFRL/PRP. During the course of the DUS&T program, a two-kilowatt system with three evaporators was developed and tested to identify viable system architectures and characterize system performance capabilities as a function of heat load profiles and spatial distribution of the evaporators. Following the successful development of the two-kilowatt system, a 10-kilowatt system with six evaporators was fabricated and tested. Tests were performed with the system operating in a totally passive, capillary-pumped mode, where applying a small amount of power to a sweepage evaporator provides the auxiliary flow through the primary evaporators, and as a self-regulating, capillary-controlled mechanically pumped system. This paper will provide a description of the 10-kilowatt multi-evaporator system and present the results of the passive and mechanically pump test programs
- Notes:
- Vendor supplied data
- Publisher Number:
- 2008-01-1997
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.