A Comparison of simulated parallax and single-station range aids to navigation : final report / Kevin Laxar and S.M. Luria ; and Marc B. Mandler.

Connect to full text Available online

View online

U.S. Government Documents Available online

View online
Format:
Book
Government document
Author/Creator:
Laxar, Kevin
Contributor:
Luria, S. M.
Mandler, Marc Bernard, 1955-
U.S. Coast Guard Research & Development Center
United States. Naval Medical Research and Development Command
Naval Submarine Medical Research Laboratory
Series:
Report (Naval Submarine Medical Research Laboratory) ; no. 1168.
Naval Submarine Medical Research Laboratory report ; no. 1168
Language:
English
Subjects (All):
Information display systems.
Aids to navigation.
Signal lights.
Range instrumentation ships--Equipment and supplies.
Range instrumentation ships.
Data Display.
Medical Subjects:
Data Display.
Physical Description:
1 online resource (iv, 34, [2] pages) : illustrations.
Place of Publication:
Groton, CT : Naval Submarine Medical Research Laboratory, [1991]
Summary:
An appropriately designed parallax (two-station) range allows a mariner to accurately determine a range line--the correct path to steer his vessel--at great distances. Less expensive alternatives to parallax ranges are desirable, and many ideas, principally single-station ranges, have been proposed. However, the mariners' abilities to establish range lines with them have not been measured. The present work has quantified the navigational sensitivity afforded by parallax ranges and three different types of single- station range display systems. The single-station ranges used (a) temporal characteristics, (b) spatial representation, or (c) color changes of signal to represent changes in lateral position. Range systems were simulated either opto- mechanically or on a high resolution computer display system. The mariners' ability to determine both lateral position in a channel and direction of motion across a channel was assessed psychophysically for each range system. Performance with single-station range systems was compared with that obtained with parallax ranges. This allowed us to evaluate the implications of replacing parallax ranges with single-station ranges.
Notes:
Title from title screen (viewed Oct. 17, 2012).
"Naval Medical Research and Development Command."
"19 April 1991."
Includes bibliographical references (pages 32-33).
Other Format:
Microfiche version: Laxar, Kevin. Comparison of simulated parallax and single-station range aids to navigation