2 options
Suggested operating procedures for aquifer pumping tests / Paul S. Osborne.
Connect to full text Available online
View online- Format:
- Book
- Government document
- Author/Creator:
- Osborne, Paul S.
- Series:
- Ground water issue
- Language:
- English
- Subjects (All):
- Groundwater--Pollution--United States.
- Groundwater.
- Groundwater--Purification--United States.
- Groundwater--Pollution.
- Groundwater--Purification.
- United States.
- Genre:
- Government publications
- Physical Description:
- 1 online resource (23 pages) : illustrations
- Place of Publication:
- [Ada, Okla.] : United States Environmental Protection Agency, Office of Research and Development, Office of Solid Waste and Emergency Response : Superfund Technology Support Center for Ground Water, Robert S. Kerr Environmental Research Laboratory, [1993]
- Summary:
- This document is intended as a primer, describing the process for the design and performance of an "aquifer test" (how to obtain reliable data from a pumping test) to obtain accurate estimates of aquifer parameters. It is intended for use by those professionals involved in characterizing sites which require corrective action as well as those which are proposed for ground water development, agricultural development, industrial development, or disposal activities. The goal of the document is to provide the reader with a complete picture of all of the elements of aquifer (pumping) test design and performance and an understanding of how those elements can affect the quality of the final data.
- Contents:
- Introduction
- Test design
- Field procedures
- Pumping test data reduction and presentation
- Analysis of test results
- Summary : example facility design
- Appendix one : equipment for data collection
- Appendix two : recording forms.
- Notes:
- Title from title screen (viewed May 26, 2004).
- "February 1993."
- "EPA/540/S-93/503."
- Includes bibliographical references.
- Electronic reproduction. [Place of publication not identified]: HathiTrust Digital Library. 2023.
- Other Format:
- Print version: Osborne, Paul S. Suggested operating procedures for aquifer pumping tests.
- OCLC:
- 55491566
- Access Restriction:
- Use copy Restrictions unspecified
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.