1 option
2024 International Building Code Illustrated Handbook , Douglas W. Thornburg, John "Buddy" Showalter
- Format:
- Book
- Author/Creator:
- Thornburg, Douglas W., author.
- Showalter, John "Buddy", author.
- Series:
- McGraw-Hill's AccessEngineeringLibrary
- Language:
- English
- Subjects (All):
- Buildings--Standards.
- Buildings.
- Architecture--Standards.
- Architecture.
- Construction industry--Standards.
- Construction industry.
- Genre:
- Electronic books
- Physical Description:
- 1 online resource (1008 pages) 600 illustrations
- Edition:
- First edition
- Place of Publication:
- New York, N.Y. McGraw Hill LLC [2025]
- Language Note:
- In English
- System Details:
- Mode of access: Internet via World Wide Web
- Summary:
- The 2024 IBC Illustrated Handbook is designed to present commentary only for those portions of the code for which commentary is helpful in furthering the understanding of the provision and its intent. This handbook uses many drawings and figures to help clarify the application and intent of many code provisions. The handbook examines the intent and application of many provisions for both the non structural- and structural-related aspects of the IBC
- Contents:
- Cover
- Title Page
- Copyright Page
- About the Authors
- Contents
- Foreword
- Preface
- Acknowledgments
- Chapter 1 Scope and Administration
- Section 101 Scope and General Requirements
- Section 102 Applicability
- Section 103 Code Compliance Agency
- Section 104 Duties and Powers of Building Official
- Section 105 Permits
- Section 107 Construction Documents
- Section 108 Temporary Structures, Equipment, and Systems
- Section 109 Fees
- Section 110 Inspections
- Section 111 Certificate of Occupancy
- Section 112 Service Utilities
- Section 113 Means of Appeals
- Section 114 Violations
- Section 115 Stop Work Order
- Section 116 Unsafe Structures and Equipment
- KEY POINTS
- Chapter 2 Definitions
- Section 201 General
- Section 202 Definitions
- Chapter 3 Occupancy Classification and Use
- Section 302 Occupancy Classification and Use Designation
- Section 303 Assembly Group A
- Section 304 Business Group B
- Section 305 Educational Group E
- Section 306 Factory Group F
- Section 307 High-Hazard Group H
- Section 308 Institutional Group I
- Section 309 Mercantile Group M
- Section 310 Residential Group R
- Section 311 Storage Group S
- Section 312 Utility and Miscellaneous Group U
- Chapter 4 Special Detailed Requirements Based on Occupancy and Use
- Section 402 Covered Mall and Open Mall Buildings
- Section 403 High-Rise Buildings
- Section 404 Atriums
- Section 405 Underground Buildings
- Section 406 Motor-Vehicle-Related Occupancies
- Section 407 Group I-2
- Section 408 Group I-3
- Section 409 Motion-Picture Projection Rooms
- Section 410 Stages, Platforms, and Technical Production Areas
- Section 411 Special Amusement Areas
- Section 412 Aircraft-Related Occupancies
- Section 413 Combustible Storage
- Section 414 Hazardous Materials
- Section 415 Groups H-1, H-2, H-3, H-4, and H-5
- Section 416 Spray Application of Flammable Finishes
- Section 417 Drying Rooms
- Section 418 Organic Coatings
- Section 420 Groups I-1, R-1, R-2, R-3, and R-4
- Section 422 Ambulatory Care Facilities
- Section 423 Storm Shelters
- Section 424 Play Structures
- Section 427 Medical Gas Systems
- Section 428 Higher Education Laboratories
- Chapter 5 General Building Heights and Areas
- Section 502 Building Address
- Section 503 General Building Height and Area Limitations
- Section 504 Building Height and Number of Stories
- Section 505 Mezzanines and Equipment Platforms
- Section 506 Building Area
- Section 507 Unlimited-Area Buildings
- Section 508 Mixed Use and Occupancy
- Section 509 Incidental Uses
- Section 510 Special Provisions
- Chapter 6 Types of Construction
- Section 602 Construction Classification
- Section 603 Combustible Material in Type I and II Construction
- Chapter 7 Fire and Smoke Protection Features
- Section 702 Multiple-Use Fire Assemblies
- Section 703 Fire-Resistance Ratings and Fire Tests
- Section 704 Fire-Resistance Rating of Structural Members
- Section 705 Exterior Walls
- Section 706 Fire Walls
- Section 707 Fire Barriers
- Section 708 Fire Partitions
- Section 709 Smoke Barriers
- Section 710 Smoke Partitions
- Section 711 Floor and Roof Assemblies
- Section 712 Vertical Openings
- Section 713 Shaft Enclosures
- Section 714 Penetrations
- Section 715 Joints and Voids
- Section 716 Opening Protectives
- Section 717 Ducts and Air Transfer Openings
- Section 718 Concealed Spaces
- Section 719 Fire-Resistance Requirements for Plaster
- Section 720 Thermal- and Sound-Insulating Materials
- Section 721 Prescriptive Fire Resistance
- Section 722 Calculated Fire Resistance
- Chapter 8 Interior Finishes
- Section 802 General
- Section 803 Wall and Ceiling Finishes
- Section 804 Interior Floor Finish
- Section 805 Combustible Materials in Types I and II Construction
- Chapter 9 Fire Protection and Life-Safety Systems
- Section 901 General
- Section 902 Fire Pump and Riser Room Size
- Section 903 Automatic Sprinkler Systems
- Section 904 Alternative Automatic Fire-Extinguishing Systems
- Section 905 Standpipe Systems
- Section 907 Fire Alarm and Detection Systems
- Section 909 Smoke Control Systems
- Section 910 Smoke and Heat Removal
- Section 911 Fire Command Center
- Section 912 Fire Department Connections
- Section 913 Fire Pumps
- Section 914 Emergency Responder Safety Features
- Section 915 Carbon Monoxide Detection
- Section 916 Gas Detection Systems
- Section 917 Mass Notification Systems
- Chapter 10 Means of Egress
- Section 1001 Administration
- Section 1002 Maintenance and Plans
- Section 1003 General Means of Egress
- Section 1004 Occupant Load
- Section 1005 Means of Egress Sizing
- Section 1006 Number of Exits and Exit Access Doorways
- Section 1007 Exit and Exit Access Doorway Configuration
- Section 1008 Means of Egress Illumination
- Section 1009 Accessible Means of Egress
- Section 1010 Doors, Gates, and Turnstiles
- Section 1011 Stairways
- Section 1012 Ramps
- Section 1013 Exit Signs
- Section 1014 Handrails
- Section 1015 Guards
- Section 1016 Exit Access
- Section 1017 Exit Access Travel Distance
- Section 1018 Aisles
- Section 1019 Exit Access Stairways and Ramps
- Section 1020 Corridors
- Section 1021 Egress Balconies
- Section 1022 Exits
- Section 1023 Interior Exit Stairways and Ramps
- Section 1024 Exit Passageways
- Section 1025 Luminous Egress Path Markings
- Section 1026 Horizontal Exits
- Section 1027 Exterior Exit Stairways and Ramps
- Section 1028 Exit Discharge
- Section 1029 Egress Courts
- Section 1030 Assembly
- Section 1031 Emergency Escape and Rescue
- Chapter 11 Accessibility
- Section 1101 General
- Section 1102 Compliance
- Section 1103 Scoping Requirements
- Section 1104 Accessible Route
- Section 1105 Accessible Entrances
- Section 1106 Parking and Passenger Loading Facilities
- Section 1107 Motor-Vehicle-Related Facilities
- Section 1108 Dwelling Units and Sleeping Units
- Section 1109 Special Occupancies
- Section 1110 Other Features and Facilities
- Section 1111 Recreational Facilities
- Section 1112 Signage
- Chapter 12 Interior Environment
- Section 1202 Ventilation
- Section 1203 Temperature Control
- Section 1204 Lighting
- Section 1205 Yards or Courts
- Section 1206 Sound Transmission
- Section 1207 Enhanced Classroom Acoustics
- Section 1208 Interior Space Dimensions
- Section 1209 Access to Unoccupied Spaces
- Section 1210 Toilet and Bathroom Requirements
- Chapter 13 Energy Efficiency
- Chapter 14 Exterior Walls
- Section 1402 Performance Requirements
- Section 1403 Materials
- Section 1404 Installation of Wall Coverings
- Section 1405 Combustible Materials on the Exterior Side of Exterior Walls
- Section 1406 Metal Composite Material (MCM)
- Section 1407 Exterior Insulation and Finish Systems
- Section 1409 Insulated Metal Panels
- Section 1412 Soffits and Fascias at Roof Overhangs
- Chapter 15 Roof Assemblies and Rooftop Structures
- Section 1504 Performance Requirements
- Section 1505 Fire Classification
- Section 1506 Materials
- Section 1507 Requirements for Roof Coverings
- Section 1511 Rooftop Structures
- Section 1512 Reroofing
- Chapter 16 Structural Design
- Section 1601 General
- Section 1602 Notations
- Section 1603 Construction Documents
- Section 1604 General Design Requirements
- Section 1605 Load Combinations
- Section 1606 Dead Loads
- Section 1607 Live Loads
- Section 1608 Snow Loads
- Section 1609 Wind Loads
- Section 1610 Soil Loads and Hydrostatic Pressure
- Section 1611 Rain Loads
- Section 1612 Flood Loads
- Section 1613 Earthquake Loads
- Section 1614 Atmospheric Ice Loads
- Section 1615 Tsunami Loads
- Section 1616 Structural Integrity
- Chapter 17 Special Inspections and Tests
- Section 1701 General
- Section 1702 New Materials
- Section 1703 Approvals
- Section 1704 Special Inspections and Tests, Contractor Responsibility, and Structural Observation
- Section 1705 Required Special Inspections and Tests
- Section 1706 Design Strengths of Materials
- Section 1707 Alternate Test Procedure
- Section 1708 In-Situ Load Tests
- Section 1709 Preconstruction Load Tests
- Chapter 18 Soils and Foundations
- Section 1801 General
- Section 1802 Design Basis
- Section 1803 Geotechnical Investigations
- Section 1804 Excavation, Grading, and Fill
- Section 1805 Dampproofing and Waterproofing
- Section 1806 Presumptive Load-Bearing Values of Soils
- Section 1807 Foundation Walls, Retaining Walls, and Embedded Posts and Poles
- Section 1808 Foundations
- Section 1809 Shallow Foundations
- Section 1810 Deep Foundations
- Chapter 19 Concrete
- Section 1901 General
- Section 1902 Coordination of Terminology
- Section 1903 Specifications for Tests and Materials
- Section 1904 Durability Requirements
- Section 1905 Seismic Requirements
- Section 1906 Footings for Light-Frame Construction
- Section 1907 Slabs-on-Ground
- Section 1908 Shotcrete
- Chapter 20 Aluminum
- Section 2002 Materials
- Chapter 21 Masonry
- Section 2101 General
- Section 2102 Notations
- Section 2103 Masonry Construction Materials
- Section 2104 Construction
- Section 2105 Quality Assurance
- Section 2106 Seismic Design
- Section 2107 Allowable Stress Design
- Section 2108 Strength Design of Masonry
- Section 2109 Empirical Design of Adobe Masonry
- Section 2110 Glass Unit Masonry
- Section 2111 Masonry Fireplaces
- Section 2112 Masonry Heaters
- Section 2113 Masonry Chimneys
- Section 2114 Dry-Stack Masonry
- Chapter 22 Steel
- Section 2201 General
- Section 2202 Structural Steel and Composite Structural Steel and Concrete
- Section 2203 Structural Stainless Steel
- Section 2204 Cold-Formed Steel
- Section 2205 Cold-Formed Stainless Steel
- Section 2206 Cold-Formed Steel Light-Frame Construction
- Section 2207 Steel Joists
- Section 2208 Steel Deck
- Section 2209 Steel Storage Racks
- Section 2210 Metal Building Systems
- Section 2211 Industrial Boltless Steel Shelving
- Section 2212 Industrial Steel Work Platforms
- Section 2213 Stairs, Ladders and Guarding for Steel Storage Racks and Industrial Steel Work Platforms
- Section 2214 Steel Cable Structures
- Chapter 23 Wood
- Section 2301 General
- Section 2302 Design Requirements
- Section 2303 Minimum Standards and Quality
- Section 2304 General Construction Requirements
- Section 2305 General Design Requirements for Lateral Force-Resisting Systems
- Section 2306 Allowable Stress Design
- Section 2307 Load and Resistance Factor Design
- Section 2308 Conventional Light-Frame Construction
- Section 2309 Wood Frame Construction Manual
- Chapter 24 Glass and Glazing
- Section 2402 Glazing Replacement
- Section 2403 General Requirements for Glass
- Section 2404 Wind, Snow, Seismic, and Dead Loads on Glass
- Section 2405 Sloped Glazing and Skylights
- Section 2406 Safety Glazing
- Section 2407 Glass in Handrails and Guards
- Section 2408 Glazing in Athletic Facilities
- Section 2409 Glass in Walkways, Elevator Hoistways, and Elevator Cars
- Chapter 25 Gypsum Panel Products and Plaster
- Section 2501 General
- Section 2508 Gypsum Construction
- Section 2510 Lathing and Furring for Cement Plaster (Stucco)
- Section 2511 Interior Plaster
- Section 2512 Exterior Plaster
- Chapter 26 Plastic
- Section 2603 Foam Plastic Insulation
- Section 2605 Plastic Veneer
- Section 2606 Light-Transmitting Plastics
- Section 2608 Light-Transmitting Plastic Glazing
- Section 2609 Light-Transmitting Plastic Roof Panels
- Section 2610 Light-Transmitting Plastic Skylight Glazing
- Chapter 27 Electrical
- Section 2702 Emergency and Standby Power Systems
- Section 2703 Lightning Protection Systems
- Chapter 28 Mechanical
- Chapter 29 Plumbing
- Section 2902 Minimum Plumbing Facilities
- Section 2903 Installation of Fixtures
- Chapter 30 Elevators and Conveying Systems
- Section 3001 General
- Section 3002 Hoistway Enclosures
- Section 3003 Emergency Operations
- Section 3006 Elevator Lobbies and Hoistway Door Protection
- Section 3007 Fire Service Access Elevator
- Section 3008 Occupant Evacuation Elevators
- Section 3009 Private Residence Elevators
- Chapter 31 Special Construction
- Section 3102 Membrane Structures
- Section 3103 Temporary Structures
- Section 3104 Pedestrian Walkways and Tunnels
- Section 3106 Marquees
- Section 3111 Solar Energy Systems
- Section 3113 Relocatable Buildings
- Section 3114 Intermodal Shipping Containers
- Chapter 32 Encroachments into the Public Right-of-Way
- Section 3201 General
- Section 3202 Encroachments
- Chapter 33 Safeguards During Construction
- Section 3301 General
- Section 3302 Owner?s Responsibility for Fire Protection
- Section 3303 Demolition
- Section 3304 Site Work
- Section 3306 Protection of Pedestrians
- Section 3307 Protection of Adjacent Property
- Section 3308 Temporary Use of Streets, Alleys, and Public Property
- Section 3309 Fire Extinguishers
- Section 3310 Means of Egress
- Section 3311 Standpipes
- Section 3313 Water Supply for Fire Protection
- Section 3314 Fire Watch During Construction
- Chapter 34 Reserved
- Chapter 35 Referenced Standards
- Appendices
- Appendix A Employee Qualifications
- Appendix B Board of Appeals
- Appendix C Group U Agricultural Buildings
- Appendix D Fire Districts
- Appendix E Supplementary Accessibility Requirements
- Appendix F Rodentproofing
- Appendix G Flood-Resistant Construction
- Appendix H Signs
- Appendix I Patio Covers
- Appendix J Grading
- Appendix K Administrative Provisions
- Appendix L Earthquake Recording Instrumentation
- Appendix M Tsunami-Generated Flood Hazard
- Appendix N Replicable Buildings
- Appendix O Performance-Based Application
- Appendix P Sleeping Lofts
- Metric Conversion Table
- Metric Units, System International (SI)
- Soft Metrication
- Hard Metrication
- Notes:
- Includes bibliographical references and index
- Electronic reproduction. New York, N.Y. : McGraw Hill, 2025. Mode of access: World Wide Web. System requirements: Web browser. Access may be restricted to users at subscribing institutions
- Description based on e-Publication PDF
- Other Format:
- Print version 2024 International Building Code Illustrated Handbook.
- ISBN:
- 9781266208836
- 1266208836
- Access Restriction:
- Restricted for use by site license
The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.