184_1017.2-2021 - IEEE Recommended Practice for Specifying Electric Submersible Pump Cable--Ethylene-Propylene Rubber Insulation / Institute of Electrical and Electronics Engineers.

IEEE Xplore (IEEE/IET Electronic Library - IEL) Available online

View online
Format:
Book
Author/Creator:
Institute of Electrical and Electronics Engineers, author, issuing body.
Language:
English
Subjects (All):
Electric cables--Congresses.
Electric cables.
Physical Description:
1 online resource (44 pages)
Place of Publication:
New York, USA : IEEE, 2022.
Summary:
Minimum requirements for the design, construction, manufacturing, testing, purchasing, and application of electric submersible pump (ESP) cable are presented. The cable is round or flat, with ethylene-propylene rubber insulation, nitrile jacket, ethylene-propylene diene monomer (EPDM) jacket or metallic barrier, and armor or encapsulating material. These cables are for voltages not exceeding 8 kV (phase to phase) and conductor temperatures not exceeding 140 ºC (284 ºF) for nitrile or a maximum of 232 ºC (450 ºF) for EPDM jacket or metallic barrier cable. Conductors, insulation, barrier (optional), assembly with or without jacket, armor, requirements for testing by the manufacturer, and cable ampacity are all covered in the document.
Notes:
Description based on publisher supplied metadata and other sources.
ISBN:
1-5044-8000-7

The Penn Libraries is committed to describing library materials using current, accurate, and responsible language. If you discover outdated or inaccurate language, please fill out this feedback form to report it and suggest alternative language.

Find

Home Release notes

My Account

Shelf Request an item Bookmarks Fines and fees Settings

Guides

Using the Find catalog Using Articles+ Using your account