1 option
IEEE Std 1019-1985 : IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene Insulation / Institute of Electrical and Electronics Engineers.
- Format:
- Book
- Author/Creator:
- Institute of Electrical and Electronics Engineers, author, issuing body.
- Language:
- English
- Subjects (All):
- Electric cables--Insulation.
- Electric cables.
- Submersible pumps.
- Physical Description:
- 1 online resource (12 pages)
- Other Title:
- IEEE Std 1019-1985: IEEE Recommended Practice for Specifying Electric Submersible Pump Cable - Polypropylene Insulation
- Place of Publication:
- Piscataway, NJ, USA : IEEE, 1984.
- Summary:
- This recommended practice establishes requirements for a three-conductor round-type oil well cable used in supplying three-phase ac electric power to submersible pump motors. Cables meeting the requirements of the recommended practice should be rated for voltages not exceeding 3 kV and for ambient temperatures not exceeding 167 F (75 C). Use of cable above rated temperature can cause premature deterioration of the insulation. The cable defined herein is not recommended for installation below a temperature of 14 F (-10 C). Voltage ratings are nominal phase-to-phase ratings.
- Notes:
- Description based on publisher supplied metadata and other sources.
- ISBN:
- 0-7381-4318-9